2.11.2 Power ON Factors
The following is the power ON factors. These factors can be set enabled or disabled using the
System Library.
Power ON Factors
The Power key is pressed while the power is off.
A time period set for the Alarm function elapsed.
The terminal is mounted on cradle while the power is being supplied by AC Adaptor via the
cradle.
Trigger key is pressed.
Reset switch on the back of the terminal is pressed.
The functions of the System Library relevant to the “Power ON Factors“ are as follows.
SysSetBootup
: Sets up “Enable” or “Disable” for turning on the power.
SysGetBootup
: Retrieves “Enabled” or “Disable” status for turning on the power.
Power ON Disable Factors
Factors that do not allow turning on the power are as follows.
When the battery pack’s voltage level is not sufficient enough to start up the terminal (VDET2
level or less).
The battery cover lock switch (at the battery compartment) is open.