4.2.6 AD-S10095A
The following table explains electrical performance on the AC Adaptors (AD-S10095AE,
AD-S10095AU).
Table 4.17
Parameter Specification Remarks
Contact : 4KV ESD
Non-contact: 8KV
RS Frequency: 80MHz to 1.0GHz
Field strength : 3V/M
EFT 1.0 KV on input AC power ports
Line to line : ±1KV (peak) Surge
Line to earth (ground) : ±2 KV (peak)
4.2.7 AD-S42120B
The following table explains electrical performance on the AC Adaptors (AD-S42120BE,
AD-S42120BE-CN).
Table 4.18
Parameter Specification Remark
Withstanding noise
Lighting surge L-L: 1.0 KV, L-FG: 2.5 KV No damage.
Anti-static strength
(ESD)
8 KV No malfunction and no damage.
Implant noise L-L, L-FG: 1 KV No malfunction and no damage.