Casio IT-2000W Specifiche Pagina 167

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 297
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 166
167
Setting ABO Time
The ABO (Auto Backlight OFF) function is used to automatically turn off the backlight if neither
key entry nor touch-panel entry is permitted for a certain period of time. This function is used to
set the ABO time. Enable ABO by selecting a number between 1 and 15, which corresponds to
a period of between 20 seconds and 5 minutes.
SYNTAX
int SYS_SetAboTime(int nValue);
INPUT
nValue = ABO time
0 Not activate ABO
1 to 15 Activates ABO in specified number x 20 seconds.
OUTPUT
= 0 Normal
= -1 Parameter error
= -3 VxD not registered
Note:
This function will be implemented by a software timer. Therefore, the period until the backlight is
actually turned off has an error of +/- 10 % associated with it.
Vedere la pagina 166
1 2 ... 162 163 164 165 166 167 168 169 170 171 172 ... 296 297

Commenti su questo manuale

Nessun commento