4.5 Low Battery Level Monitoring
For the PA-2400W there are three low battery levels available which can be used to detect low battery voltage.
Table 4.1 Battery voltage monitoring levels
Level Contents Operation Next boot-up
VDET1 Low main battery voltage alarm Indicates low main battery
voltage alarm
---
VDET2 Power off due to low main
battery voltage
Turns off the power. Resume
VDET3 Power off immediately due to
low main battery voltage.
Critical off. Warm-bootup
VDETS Low sub-battery voltage alarm Indicates low sub-battery voltage alarm.
Fig. 4.3 Voltage monitoring levels
Main battery Regulated voltage
Sub-battery
Voltage Voltage
Voltage
Condition
Good
Low
Danger
Dead or
No battery
ACL
VDET2
VDET3
VDET1
VDETS